fix: serve the device paths with or without a trailing slash
The panel's HTTP client does not follow redirects. It asks for /api/setup/ with a trailing slash, Next answered 308 to normalise it, and the firmware reported "returned code is not OK. Code - 308" and gave up. Never having obtained a token, it then called /api/display with an empty one, got 401, and told the user it could not reach the API. Not TLS, not the network, not the port — a slash. Two earlier fixes were aimed at hypotheses the evidence did not support: a certificate chain the firmware genuinely cannot validate, and a port the shop's network turned out not to block. Both were reasoned from silence, because neither Traefik nor a production Next server logs requests by default. The answer came from a packet capture, and from the device's own words. /api/log now accepts a report from a panel that cannot authenticate. Refusing it with a 401 threw away the one diagnostic that mattered: the firmware was saying exactly what was wrong and we were discarding the message. Nothing is stored — the rows would reference a device that does not exist — but it reaches the server log, and the route was already rate-limited. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_012cSY9pVhZmJUKNN7wf1Myd
This commit is contained in:
+15
-2
@@ -1,7 +1,7 @@
|
||||
import { NextResponse } from 'next/server';
|
||||
|
||||
import { authenticateDevice } from '@/lib/device/session';
|
||||
import { clientIp } from '@/lib/device/headers';
|
||||
import { clientIp, deviceHeader } from '@/lib/device/headers';
|
||||
import { checkTransport } from '@/lib/device/transport';
|
||||
import { prisma } from '@/lib/db';
|
||||
import { rateLimit } from '@/lib/ratelimit';
|
||||
@@ -34,8 +34,21 @@ export async function POST(request: Request) {
|
||||
}
|
||||
|
||||
const device = await authenticateDevice(request);
|
||||
|
||||
if (!device) {
|
||||
return NextResponse.json({ error: 'Jeton invalide' }, { status: 401 });
|
||||
// A panel that cannot authenticate is precisely the panel whose own
|
||||
// account of the failure is worth having. Refusing it with a 401 threw
|
||||
// away the one diagnostic that mattered here: the firmware was reporting
|
||||
// a 308 on /api/setup/, and we discarded the message saying so.
|
||||
//
|
||||
// Nothing is stored — the rows are tied to a device that does not exist —
|
||||
// but it reaches the server log, where `docker compose logs app` will show
|
||||
// it. The route is rate-limited above, so this is not an open write.
|
||||
const body = await request.text().catch(() => '');
|
||||
console.warn(
|
||||
`[device] journal d'un appareil non authentifié (ID: ${deviceHeader(request, 'id') ?? 'absent'}) : ${body.slice(0, 1000)}`,
|
||||
);
|
||||
return new NextResponse(null, { status: 204 });
|
||||
}
|
||||
|
||||
let entries: IncomingLog[] = [];
|
||||
|
||||